- |
Id |
Direct drive vibration machine. ( Mechanical Engineering ) A vibration machine in which the vibration table is forced to undergo a displacement by a positive linkage driven by a direct attachment to eccen-trics or camshafts. Vibradora de acción directa , ( Ingeniería mecánica ) Máquina vibradora en la que la mesa de vibración experimenta un desplazamiento producido mediante una transmisión por palancas accionadas directamente por las excéntricas o ejes de levas |
Direct drive starters , motores de arranque directo (Automóvil - Automobile). A common type of starter motor is the solenoid-operated direct drive unit. Although there are construction differences between applications , the operating principles are the same for all solenoid-shifted starter motors.
When the ignition switch is placed in the START position , the control circuit energizes the pull-in and hold-in windings of the solenoid. The solenoid plunger moves and pivots the shift lever , which in turn locates the drive pinion gear into mesh with the engine flywheel.
When the solenoid plunger is moved all the way , the contact disc closes the circuit from the battery to the starter motor. Current now flows through the field coils and the armature.
This develops the magnetic fields that cause the armature to rotate , thus turning the engine.
The direct drive starter motor can be either series-wound or compound motors.

Figura : Motor de arranque serie Delco MT operado por solenoide.
Un tipo común de motor de arranque es la unidad de accionamiento directo operada por solenoide. Aunque existen diferencias de construcción entre las aplicaciones , los principios de funcionamiento son los mismos para todos los motores de arranque con cambio de solenoide.
Cuando la llave de encendido se coloca en la posición de ARRANQUE , el circuito de control energiza los devanados de atracción y retención del solenoide. El émbolo del solenoide se mueve y mueve la palanca de cambios , que a su vez ubica el engranaje del piñón de transmisión en posición de engrane con el plato volante del motor.
Cuando el émbolo del solenoide se mueve por completo , el disco de contacto cierra el circuito de la batería con el motor de arranque. La corriente ahora fluye a través de las bobinas de campo y el inducido.
Esto desarrolla los campos magnéticos que hacen que la armadura gire , haciendo rotar el motor.
El motor de arranque de accionamiento directo puede ser tanto bobinado en serie como motor compuesto. |
Direct drive , accionamiento directo , toma directa (auto) |
Direct drive. ( Mechanical Engineering ) A drive in which the driving part is directly connected to the driven part. Transmisión directa , ( Ingeniería mecánica ) Una transmisión en la cual la parte conductora se conecta directamente a la parte conducida |
Direct -expansion coil. ( Mechanical Engineering ) A finned coil , used in air cooling , inside of which circu-lates a cold fluid or evaporating refrigerant. Ab-breviated DX coil. Serpentín de expansión directa , ( Ingeniería mecánica ) Un serpentín con aletas , utiliizado en refrigeración de aire , en el interior del cual circula un líquido frío o un refrigerante por evaporación. Abreviado serpentín DX |
Direct -feed chlorinator (water purification) , clorador de alimentación directa |
Direct feed , alimentación directa o en seco |
Direct feedback system , sistema de retroalimentación directo , ( Sistemas de control ) Sistema en el cual la retroalimentación eléctrica se utiliza directamente , como en un tacómetro |
Direct -fired furnace , horno de inyección directa |
Direct flame boiler , caldera de llama directa |
Direct gaging , aforo directo |
Direct geared . ( Mechanical Engineering ) Joined by a gear on the shaft of one machine meshing with a gear on the shaft of another machine. Engranado directamente , engrane directo , ( Ingeniería mecánica ) Unión mediante una rueda dentada montada sobre el eje de una máquina que engrana con la rueda montada sobre el eje de otra máquina |
Direct heating (building) , calefacción directa |
Direct indexing , división simple |
Direct -indirect radiator , calorífero directo-indirecto |
Direct injection (Diesel) , inyección directa |
Direct intake , toma directa |
Direct -lift hoist (truck) , elevador de efecto directo |
Direct memory access (DMA) , Acceso directo a la memoria . Es una técnica que permite a un dispositivo periférico entrar o extraer bloques de datos de la memoria principal del computador sin que intervenga el microprocesador (la unidad central de procesos -CPU). En algunos casos , la CPU puede ejecutar otras tareas mientras se lleva a cabo la transferencia directa de los datos entre el dispositivo y la memoria RAM. Este método aumenta sensiblemente la velocidad de las operaciones del computador. See: bus , DMA controller , support chips |
Direct pick-up , captación directa |
Direct process , See: Process |
Direct -projection comparator , comparador de proyección directa |
Direct rambus , Memoria para gráficos. ( Informática y Computación ). Es la tercera generación de Rambus. Sus módulos se denominan RIMM y SO-RIMM. Direct RDRAM utiliza también RSL , pero tiene una frecuencia más alta (800MHz) y mejora su eficiencia en un 95%. Un solo canal de Direct RDRAM puede transmitir un ancho de banda de 1 ,6GB por segundo. El RIMM tiene 184 pines y chips de 2 ,5 voltios. Las motherboards pueden soportar hasta tres sockets RIMM , con un máximo de 32 chips de Direct RDRAM por canal. Direct Rambus requiere que todos sus sockets estén completos para permitir el traspaso de la señal. Por este motivo , se utiliza un RIMM de continuidad en cada socket que no contenga una memoria RIMM. La tecnología Rambus es la que propononía Intel para sus desarrollos a partir del año 2000 |
Direct reading , de lectura directa |
Direct -relation telemeter , telémetro de relación directa |
Direct scanning , exploración directa |
Direct solar radiation , ( Energía solar - Solar energy ) radiación solar directa . |
Direct taxation , contribuciones directas |
Direct time lock (DTL) , Es un viejo sistema de sincronización MIDI |
Direct-vision view finder (photogrammetry) , buscador de visión directa |
|
|
583 |
Directed , dirigido |
Directed wireless telegraphy , radiografía dirigida . |
Directing , director |
Directing force , fuerza desviadora |
Directing magnet , imán corrector |
Directing wheel , rueda de orientación (molino de viento) |
Direction , dirección , dirección de imantación , sentido; aural-null direction finder , radiogoniómetro acústico; Bellini-Tosi direction finder , radiogoniómetro Bellini-Tosi; compensated loop direction finder , radiogoniómetro de cuadro compensado; crossed loops direction finder , radiogoniómetro de cuadros cruzados; gain in a direction , ganancia en una dirección; radio direction finder , radiogoniómetro , radiogoniometría; radio direction finding station , estación radiogoniométrica; Robinson direction finder , radiogoniómetro Robinson |
Direction finder (airports) , radiogoniómetro , radio brújula , antena indicadora de dirección |
Direction finding (radio) , radiogoniometría |
Direction finding unit , radiogoniómetro |
Direction indicator , indicador de dirección , intermitente , ( Ingeniería aeroespacial ) See: Directional gyro. |
Direction sign (road) , señal de dirección |
Direction switch , conmutador |
Direction transit (instruments) , tránsito no repetidor |
Directional , direccional , orientable; multi-hole directional coupler , acoplador direccional multirranura |
Directional antenna , antena direccional. Antena que irradia o recibe señales más intensamente en algunas direcciones que en otras. See: beam antenna |
Directional bit (petroleum) , barrena de perforación desviada |
Directional control valves, (hydraulics - hidráulica) Válvulas de control direccional.
In a hydraulic system, the hydraulic energy available from a pump is converted into motion and force by means of an actuator. The control of these mechanical outputs (motion and force) is one of the most important functions in a hydraulic system. The proper selection of control selection ensures the desired output and safe function of the system. In order to control the hydraulic outputs, different types of control valves are required. It is important to know various types of control valves and their functions.
There are basically three types of valves employed in hydraulic systems:
- Directional control valves
- Flow control valves
- Pressure control valves
Directional control valves play a vital role in managing energy distribution within a fluid power setup. They dictate the fluid's course and enable its movement in specific directions. These valves govern the initiation, cessation, and alteration of fluid flow direction, regulating it within hydraulic circuits. Featuring external ports for fluid entry and exit, these control valves' quantity of ports is typically denoted by the term 'way'; for instance, a valve with four ports is termed a four-way valve. In hydraulic systems, regulating the fluid flow rate is crucial for controlling the actuator's speed, accomplished through flow control valves. During system operation, pressure might gradually rise, and pressure control valves serve to maintain system pressure within the desired range, safeguarding the system. Moreover, as output force correlates directly with pressure, pressure control valves ensure the desired force output at the actuator.
Directional control valves are shown by means of several connected squares.
• The number of squares indicates the number of switching positions possible for a valve.
• Arrows within the squares indicate the flow direction.
• Lines indicate how the ports are interconnected in the various switching positions.
There are two possible methods of port designation. One method is to use the letters P, T, A, B and L, the other is to label ports alphabetically A, B, C, D, etc. The former method is generally preferred. Ports should always be labelled with the valve in the rest position. Where there is no rest position, they are allocated to the switching position assumed by the valve when the system is in its initial position.
The rest position is defined as the position automatically assumed by the valve on removal of the actuating force.
When labelling directional control valves, it is first necessary to specify the number of ports followed by the number of switching positions. Directional control valves have at least two switching positions and at least two ports. In such an instance, the valve would be designated a 2/2-way valve. The following diagrams show other directional control valves and their circuit symbols.
Methods of actuation
The switching position of a directional control valve can be modified through various activation techniques. The representation for the valve is expanded by incorporating the symbol that denotes the activation method. For certain activation methods depicted, such as push button, pedal, and lever with detent, a spring is required for resetting consistently. Resetting can also be accomplished by toggling the valve a second time, as seen in a valve equipped with a hand lever and detent setting. Outlined below are the symbols representing the most crucial activation methods. Additional methods of activation can be found in DIN ISO 1219.


Mechanical actuation - Accionamiento mecánico


En un sistema hidráulico, la energía hidráulica disponible de una bomba se convierte en movimiento y fuerza mediante un actuador. El control de estas salidas mecánicas (movimiento y fuerza) es una de las funciones más importantes en un sistema hidráulico. La selección adecuada de la selección de control garantiza la salida deseada y el funcionamiento seguro del sistema. Para controlar las salidas hidráulicas se requieren diferentes tipos de válvulas de control. Es importante conocer varios tipos de válvulas de control y sus funciones.
Básicamente existen tres tipos de válvulas empleadas en los sistemas hidráulicos:
- Válvulas de control direccional
- Válvulas de control de flujo
- Válvulas de control de presión
Las válvulas de control direccional se utilizan para controlar la distribución de energía en un sistema de potencia fluida. Ellas dan dirección al fluido y permiten su flujo en una dirección particular. Estas válvulas se emplean para controlar el inicio, detención y cambio de dirección del flujo del fluido. Regulan la dirección del flujo en el circuito hidráulico. Estas válvulas de control contienen puertos que son aberturas externas por donde el fluido entra y sale. La cantidad de puertos suele identificarse con el término 'vía'. Por ejemplo, una válvula con cuatro puertos se denomina válvula de cuatro vías. La velocidad del flujo del fluido es responsable de la velocidad del actuador (movimiento de la salida) y debe ser controlada en un sistema hidráulico. Esta operación puede realizarse mediante el uso de válvulas de control de flujo. La presión puede aumentar gradualmente cuando el sistema está en funcionamiento. Las válvulas de control de presión protegen el sistema manteniendo la presión del sistema dentro del rango deseado. Además, la fuerza de salida es directamente proporcional a la presión y, por lo tanto, las válvulas de control de presión garantizan la fuerza de salida deseada en el actuador.
Las válvulas de control direccional se muestran mediante varios cuadrados conectados.
- El número de cuadrados indica el número de posiciones de conmutación posibles para una válvula.
- Las flechas dentro de los cuadrados indican la dirección del flujo.
- Las líneas indican cómo se interconectan los puertos en las distintas posiciones de conmutación.
Hay dos métodos posibles de designación de puertos. Un método consiste en utilizar las letras P, T, A, B y L, el otro consiste en etiquetar los puertos alfabéticamente A, B, C, D, etc. Generalmente se prefiere el primer método. Los puertos siempre deben etiquetarse con la válvula en posición de reposo. Cuando no existe posición de reposo, se asignan a la posición de conmutación que asume la válvula cuando el sistema se encuentra en su posición inicial.
La posición de reposo se define como la posición que adopta automáticamente la válvula al cese la fuerza de accionamiento.
Al etiquetar válvulas de control direccional, primero es necesario especificar el número de puertos seguido del número de posiciones de conmutación. Las válvulas direccionales tienen al menos dos posiciones de conmutación y al menos dos conexiones. En tal caso, la válvula se denominaría válvula de 2/2 vías. Los siguientes diagramas muestran otras válvulas de control direccional y sus símbolos de circuito.
Métodos de actuación
La posición de conmutación de una válvula de control direccional se puede modificar mediante varias técnicas de activación. La representación de la válvula se amplía al incluir el símbolo que denota el método de activación. Para ciertos métodos de activación representados, como botón pulsador, pedal y palanca con retén, se requiere un resorte para restablecerse de manera consistente. El reinicio también se puede lograr alternando la válvula una segunda vez, como se ve en una válvula equipada con una palanca manual y un ajuste de retén. A continuación se describen los símbolos que representan los métodos de activación más importantes. Se pueden encontrar métodos de activación adicionales en DIN ISO 1219. |
|
|
584 |
#32 << Previous Page - Page #33 - Next Page >> #34
PAGES : >> 31 | 32 | 33 | 34 | 35 | Next Group >>
|
|