NEMA 4X Enclosed Motor Starter, 52A, 3PH,  Remote Start, Start/Stop, 100-250V, 36-47A


NEMA 4X Enclosed Motor Starter, 52A, 3PH, Remote Start, Start/Stop, 100-250V, 36-47A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 52A 3 Phase Separate Coil Voltage + Remote Start Terminals Start/Stop 100-250V AC/DC Coil 36-47A O/L NEMA 4X Poly - - -
**** PRICE: 741.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3120119
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 65A, 3PH, Direct Online, Start/Stop, 100-250V, 44-53A


NEMA 4X Enclosed Motor Starter, 65A, 3PH, Direct Online, Start/Stop, 100-250V, 44-53A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 65A 3 Phase Direct Online Start/Stop 100-250V AC/DC Coil 44-53A O/L NEMA 4X Poly - - -
**** PRICE: 809.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3120247
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 65A, 1PH, Direct Online, Reset Button, 100-250V, 50-60A


NEMA 4X Enclosed Motor Starter, 65A, 1PH, Direct Online, Reset Button, 100-250V, 50-60A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 65A 1 Phase Direct Online Reset Button Only 100-250V AC/DC Coil 50-60A O/L NEMA 4X Poly - - -
**** PRICE: 809.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3120384
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 16A, 1PH, Separate Coil Voltage, Reset Button, 100-250V, 10-13A


NEMA 4X Enclosed Motor Starter, 16A, 1PH, Separate Coil Voltage, Reset Button, 100-250V, 10-13A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 16A 1 Phase Separate Coil Voltage Reset Button Only 100-250V AC/DC Coil 10-13A O/L NEMA 4X Poly - - -
**** PRICE: 268.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119725
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 9A, 3PH, Direct Online, Reset Button, 100-250V, 4.2-5.7A


NEMA 4X Enclosed Motor Starter, 9A, 3PH, Direct Online, Reset Button, 100-250V, 4.2-5.7A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 9A 3 Phase Direct Online Reset Button Only 100-250V AC/DC Coil 4.2-5.7A O/L NEMA 4X Poly - - -
**** PRICE: 253.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119228
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 16A, 3PH, Remote Start Terminals, Reset Button, 250-500V, 5.7-7.6A


NEMA 4X Enclosed Motor Starter, 16A, 3PH, Remote Start Terminals, Reset Button, 250-500V, 5.7-7.6A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 16A 3 Phase Remote Start Terminals Reset Button Only 250-500V AC/DC Coil 5.7-7.6A O/L NEMA 4X Poly - - -
**** PRICE: 268.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119661
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 9A, 3PH,  Remote Start, Start/Stop, 250-500V, 4.2-5.7A


NEMA 4X Enclosed Motor Starter, 9A, 3PH, Remote Start, Start/Stop, 250-500V, 4.2-5.7A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 9A 3 Phase Separate Coil Voltage + Remote Start Terminals Start/Stop 250-500V AC/DC Coil 4.2-5.7A O/L NEMA 4X Poly - - -
**** PRICE: 253.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119227
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 16A, 1PH, Remote Start Terminals, Start/Stop, 100-250V, 10-13A


NEMA 4X Enclosed Motor Starter, 16A, 1PH, Remote Start Terminals, Start/Stop, 100-250V, 10-13A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 16A 1 Phase Remote Start Terminals Start/Stop 100-250V AC/DC Coil 10-13A O/L NEMA 4X Poly - - -
**** PRICE: 268.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119730
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 12A, 1PH,  Remote Start, Start/Stop, 100-250V, 2.3-3.1A


NEMA 4X Enclosed Motor Starter, 12A, 1PH, Remote Start, Start/Stop, 100-250V, 2.3-3.1A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 12A 1 Phase Separate Coil Voltage + Remote Start Terminals Start/Stop 100-250V AC/DC Coil 2.3-3.1A O/L NEMA 4X Poly - - -
**** PRICE: 259.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119579
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 26A, 1PH,  Remote Start, Reset Button, 24-60V, 20-24A


NEMA 4X Enclosed Motor Starter, 26A, 1PH, Remote Start, Reset Button, 24-60V, 20-24A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 26A 1 Phase Separate Control Voltage + Remote Start Terminals Reset Button Only 24-60V AC/DC Coil 20-24A O/L NEMA 4X Poly - - -
**** PRICE: 523.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119962
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 80A, 3PH,  Reset Button, 24-60V, 65-78A


NEMA 4X Enclosed Motor Starter, 80A, 3PH, Reset Button, 24-60V, 65-78A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 80A 3 Phase Separate Control Voltage Reset Button Only 24-60V AC/DC Coil 65-78A O/L NEMA 4X Poly - - -
**** PRICE: 864.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3120430
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 12A, 3PH, Separate Coil Voltage, Reset Button, 100-250V, 3.1-4.2A


NEMA 4X Enclosed Motor Starter, 12A, 3PH, Separate Coil Voltage, Reset Button, 100-250V, 3.1-4.2A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 12A 3 Phase Separate Coil Voltage Reset Button Only 100-250V AC/DC Coil 3.1-4.2A O/L NEMA 4X Poly - - -
**** PRICE: 259.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119509
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 16A, 1PH,  Reset Button, 24-60V, 16-20A


NEMA 4X Enclosed Motor Starter, 16A, 1PH, Reset Button, 24-60V, 16-20A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 16A 1 Phase Separate Control Voltage Reset Button Only 24-60V AC/DC Coil 16-20A O/L NEMA 4X Poly - - -
**** PRICE: 268.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119728
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 38A, 1PH,  Remote Start, Start/Stop, 24-60V, 35-40A


NEMA 4X Enclosed Motor Starter, 38A, 1PH, Remote Start, Start/Stop, 24-60V, 35-40A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 38A 1 Phase Separate Control Voltage + Remote Start Terminals Start/Stop 24-60V AC/DC Coil 35-40A O/L NEMA 4X Poly - - -
**** PRICE: 562.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3120042
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 16A, 3PH,  Remote Start, Reset Button, 250-500V, 16-20A


NEMA 4X Enclosed Motor Starter, 16A, 3PH, Remote Start, Reset Button, 250-500V, 16-20A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 16A 3 Phase Separate Coil Voltage + Remote Start Terminals Reset Button Only 250-500V AC/DC Coil 16-20A O/L NEMA 4X Poly - - -
**** PRICE: 268.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119665
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 80A, 1PH, Direct Online, Start/Stop, 100-250V, 57-68A


NEMA 4X Enclosed Motor Starter, 80A, 1PH, Direct Online, Start/Stop, 100-250V, 57-68A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 80A 1 Phase Direct Online Start/Stop 100-250V AC/DC Coil 57-68A O/L NEMA 4X Poly - - -
**** PRICE: 864.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3120469
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 9A, 1PH, Separate Coil Voltage, Reset Button, 100-250V, 5.7-7.6A


NEMA 4X Enclosed Motor Starter, 9A, 1PH, Separate Coil Voltage, Reset Button, 100-250V, 5.7-7.6A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 9A 1 Phase Separate Coil Voltage Reset Button Only 100-250V AC/DC Coil 5.7-7.6A O/L NEMA 4X Poly - - -
**** PRICE: 253.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119350
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 65A, 3PH, Separate Coil Voltage, Reset Button, 100-250V, 44-53A


NEMA 4X Enclosed Motor Starter, 65A, 3PH, Separate Coil Voltage, Reset Button, 100-250V, 44-53A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 65A 3 Phase Separate Coil Voltage Reset Button Only 100-250V AC/DC Coil 44-53A O/L NEMA 4X Poly - - -
**** PRICE: 809.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3120309
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 9A, 1PH,  Remote Start, Reset Button, 24-60V, 2.3-3.1A


NEMA 4X Enclosed Motor Starter, 9A, 1PH, Remote Start, Reset Button, 24-60V, 2.3-3.1A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 9A 1 Phase Separate Control Voltage + Remote Start Terminals Reset Button Only 24-60V AC/DC Coil 2.3-3.1A O/L NEMA 4X Poly - - -
**** PRICE: 253.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119392
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 80A, 1PH, Remote Start Terminals, Start/Stop, 100-250V, 48-60A


NEMA 4X Enclosed Motor Starter, 80A, 1PH, Remote Start Terminals, Start/Stop, 100-250V, 48-60A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 80A 1 Phase Remote Start Terminals Start/Stop 100-250V AC/DC Coil 48-60A O/L NEMA 4X Poly - - -
**** PRICE: 864.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3120504
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 16A, 1PH,  Remote Start, Reset Button, 24-60V, 4.2-5.7A


NEMA 4X Enclosed Motor Starter, 16A, 1PH, Remote Start, Reset Button, 24-60V, 4.2-5.7A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 16A 1 Phase Separate Control Voltage + Remote Start Terminals Reset Button Only 24-60V AC/DC Coil 4.2-5.7A O/L NEMA 4X Poly - - -
**** PRICE: 268.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119747
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 52A, 3PH,  Start/Stop, 24-60V, 44-53A


NEMA 4X Enclosed Motor Starter, 52A, 3PH, Start/Stop, 24-60V, 44-53A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 52A 3 Phase Separate Control Voltage Start/Stop 24-60V AC/DC Coil 44-53A O/L NEMA 4X Poly - - -
**** PRICE: 741.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3120132
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 52A, 3PH, Remote Start Terminals, Reset Button, 250-500V, 25-33A


NEMA 4X Enclosed Motor Starter, 52A, 3PH, Remote Start Terminals, Reset Button, 250-500V, 25-33A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 52A 3 Phase Remote Start Terminals Reset Button Only 250-500V AC/DC Coil 25-33A O/L NEMA 4X Poly - - -
**** PRICE: 741.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3120209
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 16A, 1PH, Separate Coil Voltage, Start/Stop, 100-250V, 16-20A


NEMA 4X Enclosed Motor Starter, 16A, 1PH, Separate Coil Voltage, Start/Stop, 100-250V, 16-20A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 16A 1 Phase Separate Coil Voltage Start/Stop 100-250V AC/DC Coil 16-20A O/L NEMA 4X Poly - - -
**** PRICE: 268.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119729
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 16A, 3PH, Separate Coil Voltage, Start/Stop, 250-500V, 5.7-7.6A


NEMA 4X Enclosed Motor Starter, 16A, 3PH, Separate Coil Voltage, Start/Stop, 250-500V, 5.7-7.6A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 16A 3 Phase Separate Coil Voltage Start/Stop 250-500V AC/DC Coil 5.7-7.6A O/L NEMA 4X Poly - - -
**** PRICE: 268.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119642
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 65A, 1PH,  Remote Start, Start/Stop, 24-60V, 57-67A


NEMA 4X Enclosed Motor Starter, 65A, 1PH, Remote Start, Start/Stop, 24-60V, 57-67A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 65A 1 Phase Separate Control Voltage + Remote Start Terminals Start/Stop 24-60V AC/DC Coil 57-67A O/L NEMA 4X Poly - - -
**** PRICE: 809.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3120410
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 38A, 1PH,  Remote Start, Reset Button, 24-60V, 29-35A


NEMA 4X Enclosed Motor Starter, 38A, 1PH, Remote Start, Reset Button, 24-60V, 29-35A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 38A 1 Phase Separate Control Voltage + Remote Start Terminals Reset Button Only 24-60V AC/DC Coil 29-35A O/L NEMA 4X Poly - - -
**** PRICE: 562.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3120149
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 26A, 3PH,  Remote Start, Reset Button, 100-250V, 10-13A


NEMA 4X Enclosed Motor Starter, 26A, 3PH, Remote Start, Reset Button, 100-250V, 10-13A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 26A 3 Phase Separate Coil Voltage + Remote Start Terminals Reset Button Only 100-250V AC/DC Coil 10-13A O/L NEMA 4X Poly - - -
**** PRICE: 523.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119894
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 52A, 3PH,  Remote Start, Start/Stop, 250-500V, 22-28A


NEMA 4X Enclosed Motor Starter, 52A, 3PH, Remote Start, Start/Stop, 250-500V, 22-28A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 52A 3 Phase Separate Coil Voltage + Remote Start Terminals Start/Stop 250-500V AC/DC Coil 22-28A O/L NEMA 4X Poly - - -
**** PRICE: 741.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3120151
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 12A, 1PH,  Start/Stop, 24-60V, 10-13A


NEMA 4X Enclosed Motor Starter, 12A, 1PH, Start/Stop, 24-60V, 10-13A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 12A 1 Phase Separate Control Voltage Start/Stop 24-60V AC/DC Coil 10-13A O/L NEMA 4X Poly - - -
**** PRICE: 259.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119574
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 16A, 3PH,  Remote Start, Reset Button, 24-60V, 7.6-10A


NEMA 4X Enclosed Motor Starter, 16A, 3PH, Remote Start, Reset Button, 24-60V, 7.6-10A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 16A 3 Phase Separate Control Voltage + Remote Start Terminals Reset Button Only 24-60V AC/DC Coil 7.6-10A O/L NEMA 4X Poly - - -
**** PRICE: 268.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119714
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 38A, 3PH,  Remote Start, Start/Stop, 24-60V, 20-24A


NEMA 4X Enclosed Motor Starter, 38A, 3PH, Remote Start, Start/Stop, 24-60V, 20-24A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 38A 3 Phase Separate Control Voltage + Remote Start Terminals Start/Stop 24-60V AC/DC Coil 20-24A O/L NEMA 4X Poly - - -
**** PRICE: 562.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119974
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 80A, 3PH, Separate Coil Voltage, Reset Button, 100-250V, 57-68A


NEMA 4X Enclosed Motor Starter, 80A, 3PH, Separate Coil Voltage, Reset Button, 100-250V, 57-68A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 80A 3 Phase Separate Coil Voltage Reset Button Only 100-250V AC/DC Coil 57-68A O/L NEMA 4X Poly - - -
**** PRICE: 864.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3120415
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 16A, 3PH, Direct Online, Start/Stop, 250-500V, 16-20A


NEMA 4X Enclosed Motor Starter, 16A, 3PH, Direct Online, Start/Stop, 250-500V, 16-20A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 16A 3 Phase Direct Online Start/Stop 250-500V AC/DC Coil 16-20A O/L NEMA 4X Poly - - -
**** PRICE: 268.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119603
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 16A, 1PH, Direct Online, Reset Button, 100-250V, 7.6-10A


NEMA 4X Enclosed Motor Starter, 16A, 1PH, Direct Online, Reset Button, 100-250V, 7.6-10A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 16A 1 Phase Direct Online Reset Button Only 100-250V AC/DC Coil 7.6-10A O/L NEMA 4X Poly - - -
**** PRICE: 268.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119750
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 38A, 3PH, Separate Coil Voltage, Start/Stop, 250-500V, 35-40A


NEMA 4X Enclosed Motor Starter, 38A, 3PH, Separate Coil Voltage, Start/Stop, 250-500V, 35-40A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 38A 3 Phase Separate Coil Voltage Start/Stop 250-500V AC/DC Coil 35-40A O/L NEMA 4X Poly - - -
**** PRICE: 562.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119917
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 12A, 3PH,  Start/Stop, 24-60V, 3.1-4.2A


NEMA 4X Enclosed Motor Starter, 12A, 3PH, Start/Stop, 24-60V, 3.1-4.2A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 12A 3 Phase Separate Control Voltage Start/Stop 24-60V AC/DC Coil 3.1-4.2A O/L NEMA 4X Poly - - -
**** PRICE: 259.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119407
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 38A, 3PH, Remote Start Terminals, Reset Button, 100-250V, 24-29A


NEMA 4X Enclosed Motor Starter, 38A, 3PH, Remote Start Terminals, Reset Button, 100-250V, 24-29A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 38A 3 Phase Remote Start Terminals Reset Button Only 100-250V AC/DC Coil 24-29A O/L NEMA 4X Poly - - -
**** PRICE: 562.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119993
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 65A, 3PH, Remote Start Terminals, Start/Stop, 250-500V, 44-53A


NEMA 4X Enclosed Motor Starter, 65A, 3PH, Remote Start Terminals, Start/Stop, 250-500V, 44-53A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 65A 3 Phase Remote Start Terminals Start/Stop 250-500V AC/DC Coil 44-53A O/L NEMA 4X Poly - - -
**** PRICE: 809.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3120286
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 52A, 3PH, Direct Online, Start/Stop, 100-250V, 44-53A


NEMA 4X Enclosed Motor Starter, 52A, 3PH, Direct Online, Start/Stop, 100-250V, 44-53A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 52A 3 Phase Direct Online Start/Stop 100-250V AC/DC Coil 44-53A O/L NEMA 4X Poly - - -
**** PRICE: 741.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3120140
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 80A, 1PH, Separate Coil Voltage, Start/Stop, 100-250V, 65-78A


NEMA 4X Enclosed Motor Starter, 80A, 1PH, Separate Coil Voltage, Start/Stop, 100-250V, 65-78A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 80A 1 Phase Separate Coil Voltage Start/Stop 100-250V AC/DC Coil 65-78A O/L NEMA 4X Poly - - -
**** PRICE: 864.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3120486
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 9A, 3PH, Remote Start Terminals, Start/Stop, 250-500V, 7.6-10A


NEMA 4X Enclosed Motor Starter, 9A, 3PH, Remote Start Terminals, Start/Stop, 250-500V, 7.6-10A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 9A 3 Phase Remote Start Terminals Start/Stop 250-500V AC/DC Coil 7.6-10A O/L NEMA 4X Poly - - -
**** PRICE: 253.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119223
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 38A, 3PH, Remote Start Terminals, Reset Button, 250-500V, 24-29A


NEMA 4X Enclosed Motor Starter, 38A, 3PH, Remote Start Terminals, Reset Button, 250-500V, 24-29A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 38A 3 Phase Remote Start Terminals Reset Button Only 250-500V AC/DC Coil 24-29A O/L NEMA 4X Poly - - -
**** PRICE: 562.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119994
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 52A, 3PH,  Reset Button, 24-60V, 36-47A


NEMA 4X Enclosed Motor Starter, 52A, 3PH, Reset Button, 24-60V, 36-47A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 52A 3 Phase Separate Control Voltage Reset Button Only 24-60V AC/DC Coil 36-47A O/L NEMA 4X Poly - - -
**** PRICE: 741.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3120220
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 12A, 3PH, Direct Online, Start/Stop, 100-250V, 10-13A


NEMA 4X Enclosed Motor Starter, 12A, 3PH, Direct Online, Start/Stop, 100-250V, 10-13A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 12A 3 Phase Direct Online Start/Stop 100-250V AC/DC Coil 10-13A O/L NEMA 4X Poly - - -
**** PRICE: 259.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119464
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 16A, 1PH, Remote Start Terminals, Start/Stop, 100-250V, 7.6-10A


NEMA 4X Enclosed Motor Starter, 16A, 1PH, Remote Start Terminals, Start/Stop, 100-250V, 7.6-10A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 16A 1 Phase Remote Start Terminals Start/Stop 100-250V AC/DC Coil 7.6-10A O/L NEMA 4X Poly - - -
**** PRICE: 268.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119777
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 80A, 1PH,  Remote Start, Reset Button, 24-60V, 57-68A


NEMA 4X Enclosed Motor Starter, 80A, 1PH, Remote Start, Reset Button, 24-60V, 57-68A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 80A 1 Phase Separate Control Voltage + Remote Start Terminals Reset Button Only 24-60V AC/DC Coil 57-68A O/L NEMA 4X Poly - - -
**** PRICE: 864.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3120492
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 52A, 1PH,  Remote Start, Reset Button, 100-250V, 36-47A


NEMA 4X Enclosed Motor Starter, 52A, 1PH, Remote Start, Reset Button, 100-250V, 36-47A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 52A 1 Phase Separate Coil Voltage + Remote Start Terminals Reset Button Only 100-250V AC/DC Coil 36-47A O/L NEMA 4X Poly - - -
**** PRICE: 741.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3120243
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 38A, 3PH,  Remote Start, Start/Stop, 100-250V, 35-40A


NEMA 4X Enclosed Motor Starter, 38A, 3PH, Remote Start, Start/Stop, 100-250V, 35-40A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 38A 3 Phase Separate Coil Voltage + Remote Start Terminals Start/Stop 100-250V AC/DC Coil 35-40A O/L NEMA 4X Poly - - -
**** PRICE: 562.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3120013
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 26A, 1PH, Remote Start Terminals, Start/Stop, 100-250V, 13-16A


NEMA 4X Enclosed Motor Starter, 26A, 1PH, Remote Start Terminals, Start/Stop, 100-250V, 13-16A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 26A 1 Phase Remote Start Terminals Start/Stop 100-250V AC/DC Coil 13-16A O/L NEMA 4X Poly - - -
**** PRICE: 523.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119868
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 26A, 1PH,  Remote Start, Reset Button, 100-250V, 16-20A


NEMA 4X Enclosed Motor Starter, 26A, 1PH, Remote Start, Reset Button, 100-250V, 16-20A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 26A 1 Phase Separate Coil Voltage + Remote Start Terminals Reset Button Only 100-250V AC/DC Coil 16-20A O/L NEMA 4X Poly - - -
**** PRICE: 523.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119963
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 9A, 3PH, Remote Start Terminals, Reset Button, 250-500V, 4.2-5.7A


NEMA 4X Enclosed Motor Starter, 9A, 3PH, Remote Start Terminals, Reset Button, 250-500V, 4.2-5.7A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 9A 3 Phase Remote Start Terminals Reset Button Only 250-500V AC/DC Coil 4.2-5.7A O/L NEMA 4X Poly - - -
**** PRICE: 253.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119298
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 38A, 1PH, Remote Start Terminals, Reset Button, 100-250V, 29-35A


NEMA 4X Enclosed Motor Starter, 38A, 1PH, Remote Start Terminals, Reset Button, 100-250V, 29-35A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 38A 1 Phase Remote Start Terminals Reset Button Only 100-250V AC/DC Coil 29-35A O/L NEMA 4X Poly - - -
**** PRICE: 562.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3120074
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 38A, 3PH,  Reset Button, 24-60V, 24-29A


NEMA 4X Enclosed Motor Starter, 38A, 3PH, Reset Button, 24-60V, 24-29A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 38A 3 Phase Separate Control Voltage Reset Button Only 24-60V AC/DC Coil 24-29A O/L NEMA 4X Poly - - -
**** PRICE: 562.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119998
UPC:
Tags: | Construction. Industrial supply

Start of page
Advance Controls 133044, Compact Starter w/Reset only, 22-30 amps, 120V, C28 Contactor


Advance Controls 133044, Compact Starter w/Reset only, 22-30 amps, 120V, C28 Contactor
Business & Industrial
Global Industrial
ACI's Compact Motor Starters are a Ready to Use solution for many electric motor applications. Available with Start/Stop/Overload Reset or just Reset Button. Adjustable Overload, differential single phase protection on three phase units, wide range contactor coils. Coil voltage can be the same voltage as motor line voltage or can be controlled from a different source at a lower voltage. - - -
**** PRICE: 194.95 USD
Manufacturer : ADVANCE CONTROLS INC.
SKU: B613480
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 26A, 1PH, Direct Online, Start/Stop, 100-250V, 24-29A


NEMA 4X Enclosed Motor Starter, 26A, 1PH, Direct Online, Start/Stop, 100-250V, 24-29A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 26A 1 Phase Direct Online Start/Stop 100-250V AC/DC Coil 24-29A O/L NEMA 4X Poly - - -
**** PRICE: 523.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119885
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 9A, 3PH, Remote Start Terminals, Reset Button, 250-500V, 3.1-4.2A


NEMA 4X Enclosed Motor Starter, 9A, 3PH, Remote Start Terminals, Reset Button, 250-500V, 3.1-4.2A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 9A 3 Phase Remote Start Terminals Reset Button Only 250-500V AC/DC Coil 3.1-4.2A O/L NEMA 4X Poly - - -
**** PRICE: 253.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119286
UPC:
Tags: | Construction. Industrial supply

Start of page
Advance Controls 133120, Three Phase Compact Starter w/Start-Stop Reset 1.4-2.1 amps - 120 VAC


Advance Controls 133120, Three Phase Compact Starter w/Start-Stop Reset 1.4-2.1 amps - 120 VAC
Business & Industrial
Global Industrial
ACI's Compact Motor Starters are a Ready to Use solution for many electric motor applications. Available with Start/Stop/Overload Reset or just Reset Button. Adjustable Overload, differential single phase protection on three phase units, wide range contactor coils. Coil voltage can be the same voltage as motor line voltage or can be controlled from a different source at a lower voltage. - - -
**** PRICE: 164.95 USD
Manufacturer : ADVANCE CONTROLS INC.
SKU: B613485
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 38A, 3PH, Remote Start Terminals, Start/Stop, 100-250V, 29-35A


NEMA 4X Enclosed Motor Starter, 38A, 3PH, Remote Start Terminals, Start/Stop, 100-250V, 29-35A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 38A 3 Phase Remote Start Terminals Start/Stop 100-250V AC/DC Coil 29-35A O/L NEMA 4X Poly - - -
**** PRICE: 562.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119976
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 12A, 3PH,  Remote Start, Reset Button, 100-250V, 10-13A


NEMA 4X Enclosed Motor Starter, 12A, 3PH, Remote Start, Reset Button, 100-250V, 10-13A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 12A 3 Phase Separate Coil Voltage + Remote Start Terminals Reset Button Only 100-250V AC/DC Coil 10-13A O/L NEMA 4X Poly - - -
**** PRICE: 259.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119505
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 38A, 1PH,  Reset Button, 24-60V, 16-20A


NEMA 4X Enclosed Motor Starter, 38A, 1PH, Reset Button, 24-60V, 16-20A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 38A 1 Phase Separate Control Voltage Reset Button Only 24-60V AC/DC Coil 16-20A O/L NEMA 4X Poly - - -
**** PRICE: 562.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3120092
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 26A, 1PH, Direct Online, Start/Stop, 100-250V, 13-16A


NEMA 4X Enclosed Motor Starter, 26A, 1PH, Direct Online, Start/Stop, 100-250V, 13-16A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 26A 1 Phase Direct Online Start/Stop 100-250V AC/DC Coil 13-16A O/L NEMA 4X Poly - - -
**** PRICE: 523.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119881
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 80A, 3PH, Direct Online, Reset Button, 250-500V, 48-60A


NEMA 4X Enclosed Motor Starter, 80A, 3PH, Direct Online, Reset Button, 250-500V, 48-60A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 80A 3 Phase Direct Online Reset Button Only 250-500V AC/DC Coil 48-60A O/L NEMA 4X Poly - - -
**** PRICE: 864.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3120456
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 12A, 1PH, Direct Online, Start/Stop, 100-250V, 7.6-10A


NEMA 4X Enclosed Motor Starter, 12A, 1PH, Direct Online, Start/Stop, 100-250V, 7.6-10A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 12A 1 Phase Direct Online Start/Stop 100-250V AC/DC Coil 7.6-10A O/L NEMA 4X Poly - - -
**** PRICE: 259.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119512
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 9A, 3PH,  Remote Start, Start/Stop, 250-500V, 3.1-4.2A


NEMA 4X Enclosed Motor Starter, 9A, 3PH, Remote Start, Start/Stop, 250-500V, 3.1-4.2A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 9A 3 Phase Separate Coil Voltage + Remote Start Terminals Start/Stop 250-500V AC/DC Coil 3.1-4.2A O/L NEMA 4X Poly - - -
**** PRICE: 253.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119274
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 26A, 1PH, Remote Start Terminals, Start/Stop, 100-250V, 24-29A


NEMA 4X Enclosed Motor Starter, 26A, 1PH, Remote Start Terminals, Start/Stop, 100-250V, 24-29A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 26A 1 Phase Remote Start Terminals Start/Stop 100-250V AC/DC Coil 24-29A O/L NEMA 4X Poly - - -
**** PRICE: 523.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119873
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 12A, 1PH, Remote Start Terminals, Reset Button, 100-250V, 2.3-3.1A


NEMA 4X Enclosed Motor Starter, 12A, 1PH, Remote Start Terminals, Reset Button, 100-250V, 2.3-3.1A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 12A 1 Phase Remote Start Terminals Reset Button Only 100-250V AC/DC Coil 2.3-3.1A O/L NEMA 4X Poly - - -
**** PRICE: 259.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119589
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 80A, 3PH, Direct Online, Reset Button, 100-250V, 48-60A


NEMA 4X Enclosed Motor Starter, 80A, 3PH, Direct Online, Reset Button, 100-250V, 48-60A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 80A 3 Phase Direct Online Reset Button Only 100-250V AC/DC Coil 48-60A O/L NEMA 4X Poly - - -
**** PRICE: 864.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3120459
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 12A, 3PH, Remote Start Terminals, Start/Stop, 250-500V, 5.7-7.6A


NEMA 4X Enclosed Motor Starter, 12A, 3PH, Remote Start Terminals, Start/Stop, 250-500V, 5.7-7.6A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 12A 3 Phase Remote Start Terminals Start/Stop 250-500V AC/DC Coil 5.7-7.6A O/L NEMA 4X Poly - - -
**** PRICE: 259.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119457
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 38A, 1PH,  Remote Start, Start/Stop, 100-250V, 29-35A


NEMA 4X Enclosed Motor Starter, 38A, 1PH, Remote Start, Start/Stop, 100-250V, 29-35A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 38A 1 Phase Separate Coil Voltage + Remote Start Terminals Start/Stop 100-250V AC/DC Coil 29-35A O/L NEMA 4X Poly - - -
**** PRICE: 562.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3120039
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 12A, 3PH, Remote Start Terminals, Start/Stop, 250-500V, 7.6-10A


NEMA 4X Enclosed Motor Starter, 12A, 3PH, Remote Start Terminals, Start/Stop, 250-500V, 7.6-10A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 12A 3 Phase Remote Start Terminals Start/Stop 250-500V AC/DC Coil 7.6-10A O/L NEMA 4X Poly - - -
**** PRICE: 259.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119414
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 52A, 3PH, Remote Start Terminals, Reset Button, 250-500V, 36-47A


NEMA 4X Enclosed Motor Starter, 52A, 3PH, Remote Start Terminals, Reset Button, 250-500V, 36-47A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 52A 3 Phase Remote Start Terminals Reset Button Only 250-500V AC/DC Coil 36-47A O/L NEMA 4X Poly - - -
**** PRICE: 741.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3120182
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 65A, 3PH, Separate Coil Voltage, Start/Stop, 250-500V, 50-60A


NEMA 4X Enclosed Motor Starter, 65A, 3PH, Separate Coil Voltage, Start/Stop, 250-500V, 50-60A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 65A 3 Phase Separate Coil Voltage Start/Stop 250-500V AC/DC Coil 50-60A O/L NEMA 4X Poly - - -
**** PRICE: 809.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3120267
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 16A, 1PH,  Start/Stop, 24-60V, 10-13A


NEMA 4X Enclosed Motor Starter, 16A, 1PH, Start/Stop, 24-60V, 10-13A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 16A 1 Phase Separate Control Voltage Start/Stop 24-60V AC/DC Coil 10-13A O/L NEMA 4X Poly - - -
**** PRICE: 268.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119753
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 52A, 1PH, Separate Coil Voltage, Start/Stop, 100-250V, 25-33A


NEMA 4X Enclosed Motor Starter, 52A, 1PH, Separate Coil Voltage, Start/Stop, 100-250V, 25-33A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 52A 1 Phase Separate Coil Voltage Start/Stop 100-250V AC/DC Coil 25-33A O/L NEMA 4X Poly - - -
**** PRICE: 741.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3120206
UPC:
Tags: | Construction. Industrial supply

Start of page
Advance Controls 133099, Three Phase Compact Starter w/Reset only 12.5-18 amps - 24 VAC


Advance Controls 133099, Three Phase Compact Starter w/Reset only 12.5-18 amps - 24 VAC
Business & Industrial
Global Industrial
ACI's Compact Motor Starters are a Ready to Use solution for many electric motor applications. Available with Start/Stop/Overload Reset or just Reset Button. Adjustable Overload, differential single phase protection on three phase units, wide range contactor coils. Coil voltage can be the same voltage as motor line voltage or can be controlled from a different source at a lower voltage. - - -
**** PRICE: 170.95 USD
Manufacturer : ADVANCE CONTROLS INC.
SKU: B613889
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 38A, 1PH,  Remote Start, Start/Stop, 24-60V, 16-20A


NEMA 4X Enclosed Motor Starter, 38A, 1PH, Remote Start, Start/Stop, 24-60V, 16-20A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 38A 1 Phase Separate Control Voltage + Remote Start Terminals Start/Stop 24-60V AC/DC Coil 16-20A O/L NEMA 4X Poly - - -
**** PRICE: 562.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3120041
UPC:
Tags: | Construction. Industrial supply

Start of page
Advance Controls 133129, Three Phase Compact Starter w/Start-Stop Reset 2.4-3.6 amps - 24 VAC


Advance Controls 133129, Three Phase Compact Starter w/Start-Stop Reset 2.4-3.6 amps - 24 VAC
Business & Industrial
Global Industrial
ACI's Compact Motor Starters are a Ready to Use solution for many electric motor applications. Available with Start/Stop/Overload Reset or just Reset Button. Adjustable Overload, differential single phase protection on three phase units, wide range contactor coils. Coil voltage can be the same voltage as motor line voltage or can be controlled from a different source at a lower voltage. - - -
**** PRICE: 164.95 USD
Manufacturer : ADVANCE CONTROLS INC.
SKU: B613496
UPC:
Tags: | Construction. Industrial supply

Start of page
Advance Controls 133087, Three Phase Compact Starter w/Reset only 3.5-5.0 amps - 460 VAC


Advance Controls 133087, Three Phase Compact Starter w/Reset only 3.5-5.0 amps - 460 VAC
Business & Industrial
Global Industrial
ACI's Compact Motor Starters are a Ready to Use solution for many electric motor applications. Available with Start/Stop/Overload Reset or just Reset Button. Adjustable Overload, differential single phase protection on three phase units, wide range contactor coils. Coil voltage can be the same voltage as motor line voltage or can be controlled from a different source at a lower voltage. - - -
**** PRICE: 147.95 USD
Manufacturer : ADVANCE CONTROLS INC.
SKU: B613897
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 26A, 3PH, Remote Start Terminals, Reset Button, 250-500V, 20-24A


NEMA 4X Enclosed Motor Starter, 26A, 3PH, Remote Start Terminals, Reset Button, 250-500V, 20-24A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 26A 3 Phase Remote Start Terminals Reset Button Only 250-500V AC/DC Coil 20-24A O/L NEMA 4X Poly - - -
**** PRICE: 523.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119845
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 26A, 1PH, Remote Start Terminals, Start/Stop, 100-250V, 20-24A


NEMA 4X Enclosed Motor Starter, 26A, 1PH, Remote Start Terminals, Start/Stop, 100-250V, 20-24A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 26A 1 Phase Remote Start Terminals Start/Stop 100-250V AC/DC Coil 20-24A O/L NEMA 4X Poly - - -
**** PRICE: 523.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119857
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 80A, 3PH,  Remote Start, Reset Button, 250-500V, 75-87A


NEMA 4X Enclosed Motor Starter, 80A, 3PH, Remote Start, Reset Button, 250-500V, 75-87A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 80A 3 Phase Separate Coil Voltage + Remote Start Terminals Reset Button Only 250-500V AC/DC Coil 75-87A O/L NEMA 4X Poly - - -
**** PRICE: 864.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3120468
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 38A, 3PH, Separate Coil Voltage, Reset Button, 100-250V, 20-24A


NEMA 4X Enclosed Motor Starter, 38A, 3PH, Separate Coil Voltage, Reset Button, 100-250V, 20-24A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 38A 3 Phase Separate Coil Voltage Reset Button Only 100-250V AC/DC Coil 20-24A O/L NEMA 4X Poly - - -
**** PRICE: 562.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119991
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 12A, 1PH,  Reset Button, 24-60V, 10-13A


NEMA 4X Enclosed Motor Starter, 12A, 1PH, Reset Button, 24-60V, 10-13A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 12A 1 Phase Separate Control Voltage Reset Button Only 24-60V AC/DC Coil 10-13A O/L NEMA 4X Poly - - -
**** PRICE: 259.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119540
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 9A, 3PH,  Remote Start, Reset Button, 250-500V, 7.6-10A


NEMA 4X Enclosed Motor Starter, 9A, 3PH, Remote Start, Reset Button, 250-500V, 7.6-10A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 9A 3 Phase Separate Coil Voltage + Remote Start Terminals Reset Button Only 250-500V AC/DC Coil 7.6-10A O/L NEMA 4X Poly - - -
**** PRICE: 253.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119324
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 38A, 3PH, Direct Online, Reset Button, 100-250V, 16-20A


NEMA 4X Enclosed Motor Starter, 38A, 3PH, Direct Online, Reset Button, 100-250V, 16-20A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 38A 3 Phase Direct Online Reset Button Only 100-250V AC/DC Coil 16-20A O/L NEMA 4X Poly - - -
**** PRICE: 562.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119987
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 16A, 3PH,  Remote Start, Reset Button, 250-500V, 13-16A


NEMA 4X Enclosed Motor Starter, 16A, 3PH, Remote Start, Reset Button, 250-500V, 13-16A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 16A 3 Phase Separate Coil Voltage + Remote Start Terminals Reset Button Only 250-500V AC/DC Coil 13-16A O/L NEMA 4X Poly - - -
**** PRICE: 268.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119712
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 12A, 3PH, Direct Online, Reset Button, 100-250V, 2.3-3.1A


NEMA 4X Enclosed Motor Starter, 12A, 3PH, Direct Online, Reset Button, 100-250V, 2.3-3.1A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 12A 3 Phase Direct Online Reset Button Only 100-250V AC/DC Coil 2.3-3.1A O/L NEMA 4X Poly - - -
**** PRICE: 259.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119429
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 12A, 3PH, Separate Coil Voltage, Reset Button, 250-500V, 3.1-4.2A


NEMA 4X Enclosed Motor Starter, 12A, 3PH, Separate Coil Voltage, Reset Button, 250-500V, 3.1-4.2A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 12A 3 Phase Separate Coil Voltage Reset Button Only 250-500V AC/DC Coil 3.1-4.2A O/L NEMA 4X Poly - - -
**** PRICE: 259.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119483
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 9A, 1PH, Remote Start Terminals, Reset Button, 100-250V, 7.6-10A


NEMA 4X Enclosed Motor Starter, 9A, 1PH, Remote Start Terminals, Reset Button, 100-250V, 7.6-10A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 9A 1 Phase Remote Start Terminals Reset Button Only 100-250V AC/DC Coil 7.6-10A O/L NEMA 4X Poly - - -
**** PRICE: 253.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119395
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 26A, 3PH,  Remote Start, Reset Button, 100-250V, 13-16A


NEMA 4X Enclosed Motor Starter, 26A, 3PH, Remote Start, Reset Button, 100-250V, 13-16A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 26A 3 Phase Separate Coil Voltage + Remote Start Terminals Reset Button Only 100-250V AC/DC Coil 13-16A O/L NEMA 4X Poly - - -
**** PRICE: 523.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119843
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 12A, 1PH, Remote Start Terminals, Start/Stop, 100-250V, 5.7-7.6A


NEMA 4X Enclosed Motor Starter, 12A, 1PH, Remote Start Terminals, Start/Stop, 100-250V, 5.7-7.6A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 12A 1 Phase Remote Start Terminals Start/Stop 100-250V AC/DC Coil 5.7-7.6A O/L NEMA 4X Poly - - -
**** PRICE: 259.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119549
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 12A, 1PH,  Remote Start, Start/Stop, 24-60V, 5.7-7.6A


NEMA 4X Enclosed Motor Starter, 12A, 1PH, Remote Start, Start/Stop, 24-60V, 5.7-7.6A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 12A 1 Phase Separate Control Voltage + Remote Start Terminals Start/Stop 24-60V AC/DC Coil 5.7-7.6A O/L NEMA 4X Poly - - -
**** PRICE: 259.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119531
UPC:
Tags: | Construction. Industrial supply

Start of page
Advance Controls 133077, Three Phase Compact Starter w/Reset only 1.8-2.7 amps - 460 VAC


Advance Controls 133077, Three Phase Compact Starter w/Reset only 1.8-2.7 amps - 460 VAC
Business & Industrial
Global Industrial
ACI's Compact Motor Starters are a Ready to Use solution for many electric motor applications. Available with Start/Stop/Overload Reset or just Reset Button. Adjustable Overload, differential single phase protection on three phase units, wide range contactor coils. Coil voltage can be the same voltage as motor line voltage or can be controlled from a different source at a lower voltage. - - -
**** PRICE: 172.95 USD
Manufacturer : ADVANCE CONTROLS INC.
SKU: B613786
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 38A, 1PH, Direct Online, Reset Button, 100-250V, 35-40A


NEMA 4X Enclosed Motor Starter, 38A, 1PH, Direct Online, Reset Button, 100-250V, 35-40A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 38A 1 Phase Direct Online Reset Button Only 100-250V AC/DC Coil 35-40A O/L NEMA 4X Poly - - -
**** PRICE: 562.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3120076
UPC:
Tags: | Construction. Industrial supply

Start of page
Advance Controls 133149, Three Phase Compact Starter w/Start-Stop Reset 12.5-18 amps - 24 VAC


Advance Controls 133149, Three Phase Compact Starter w/Start-Stop Reset 12.5-18 amps - 24 VAC
Business & Industrial
Global Industrial
ACI's Compact Motor Starters are a Ready to Use solution for many electric motor applications. Available with Start/Stop/Overload Reset or just Reset Button. Adjustable Overload, differential single phase protection on three phase units, wide range contactor coils. Coil voltage can be the same voltage as motor line voltage or can be controlled from a different source at a lower voltage. - - -
**** PRICE: 177.95 USD
Manufacturer : ADVANCE CONTROLS INC.
SKU: B613366
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 12A, 3PH, Separate Coil Voltage, Start/Stop, 250-500V, 2.3-3.1A


NEMA 4X Enclosed Motor Starter, 12A, 3PH, Separate Coil Voltage, Start/Stop, 250-500V, 2.3-3.1A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 12A 3 Phase Separate Coil Voltage Start/Stop 250-500V AC/DC Coil 2.3-3.1A O/L NEMA 4X Poly - - -
**** PRICE: 259.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119410
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 9A, 3PH,  Remote Start, Start/Stop, 24-60V, 4.2-5.7A


NEMA 4X Enclosed Motor Starter, 9A, 3PH, Remote Start, Start/Stop, 24-60V, 4.2-5.7A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 9A 3 Phase Separate Control Voltage + Remote Start Terminals Start/Stop 24-60V AC/DC Coil 4.2-5.7A O/L NEMA 4X Poly - - -
**** PRICE: 253.95 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3119224
UPC:
Tags: | Construction. Industrial supply

Start of page
NEMA 4X Enclosed Motor Starter, 80A, 3PH, Direct Online, Reset Button, 250-500V, 65-78A


NEMA 4X Enclosed Motor Starter, 80A, 3PH, Direct Online, Reset Button, 250-500V, 65-78A
Business & Industrial
Global Industrial
Springer controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay and a NEMA 4X rated polycarbonate enclosure. To select the proper starter for your requirements: 1) Refer to the motor or equipment nameplate to verify the Full Load Amperage (FLA) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (Amps) higher than the FLA of your motor. 2) Choose the control power used to close the contactor. 3) Choose the overload by selecting a current range that contains the FLA of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria: 4) Incoming power: If the line power will be used as the control power as well, this is referred to as a "direct-online starter": If the control voltage is not the same as the line voltage we refer to this as "separate control voltage": If the starter needs to be activated from an external switch, we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" It is assumed, in this arrangement that the line voltage and control voltage are the sameIf you would like remote start terminals and will be using different voltage for line power and control power, we refer to this as "separate control voltage + remote start terminals" Features: 80A 3 Phase Direct Online Reset Button Only 250-500V AC/DC Coil 65-78A O/L NEMA 4X Poly - - -
**** PRICE: 864.00 USD
Manufacturer : SPRINGER CONTROLS CO. INC
SKU: B3120425
UPC:
Tags: | Construction. Industrial supply

Start of page
Advance Controls 133040, Compact Starter w/Reset only, 17-24 amps, 120V, C16 Contactor


Advance Controls 133040, Compact Starter w/Reset only, 17-24 amps, 120V, C16 Contactor
Business & Industrial
Global Industrial
ACI's Compact Motor Starters are a Ready to Use solution for many electric motor applications. Available with Start/Stop/Overload Reset or just Reset Button. Adjustable Overload, differential single phase protection on three phase units, wide range contactor coils. Coil voltage can be the same voltage as motor line voltage or can be controlled from a different source at a lower voltage. - - -
**** PRICE: 164.95 USD